Category Specification
Manufacturer Part No RKL4308
Cable type Basic cable
Number of cores and conductor nominal cross-section (4G2.5 + 2x(2×1.5)C)C
Outer diameter (max) [mm] 16
Weight per km [kg/km] 383
Copper index [kg/km] 254
Min. bend radius, e-chain (factor) [x d] 7.5
Min. bend radius, e-chain [mm] 120
Min. bend radius, flexible (factor) [x d] 6
Min. bend radius, fixed (factor) [x d] 4
Temperature e-chain® -25°C up to +80°C
Temperature, flexible -40°C to +80°C (according to DIN EN 60811-504)
Temperature, fixed -50°C to +80°C (according to DIN EN 50305)
Max unsupported speed [m/s] 10
Max gliding speed [m/s] 5
Max acceleration [m/s²] 80
Nominal voltage 600/1,000 V (according to DIN VDE 0298-3)
UL Voltage Rating [V] 1000
Test voltage 4000 V (according to DIN EN 50395)
Core conductor Stranded conductor, especially bend-resistant bare copper wires (DIN EN 60228)
Core insulation Mechanically high-quality, low-capacity XLPE mixture
Core stranding Power cores with control pair elements wound with elements for high-tensile stresses
Core group 1 core structure 4G2.5
Core group 2 core structure 2x(2×1.5)C)C
Element shield Extremely bend-resistant braiding of tinned copper wires
Inner jacket TPE mixture adapted for e-chains® requirements
Overall shield Extremely flexible braiding of tinned copper wires; linear coverage ~70%, optical ~90%
Outer jacket Low-adhesion, halogen-free, highly abrasion-resistant PUR mixture (DIN EN 50363-10-2)
Outer jacket colour Pastel orange (similar to RAL 2003)
CFRIP® Tear strip moulded into inner jacket for faster stripping
UV resistance Medium
Oil resistance Oil-resistant, Class 3 (DIN EN 50363-10-2)
Offshore MUD-resistant (NEK 606 – status 2018)
Flame retardant IEC 60332-1-2, Cable Flame, VW-1, FT1, FT2/Horizontal Flame
Silicone-free Free from silicone affecting paint adhesion (PV 3.10.7 – status 1992)
Halogen-free According to DIN EN 60754
UL verified Certificate no. V293650: “igus 4-year chainflex cable guarantee and service life calculator”
NFPA According to NFPA 79-2018, chapter 12.9
DNV Type approval certificate TAE00003XA
REACH In accordance with Regulation (EC) No. 1907/2006
Lead-free According to 2011/65/EU (RoHs-II/RoHS-III)
Cleanroom ISO Class 1; outer jacket complies with CF77.UL.05.12.D – tested by IPA (DIN EN ISO 14644-1)
DESINA According to VDW, DESINA standardisation
CE According to 2014/35/EU
Plug Connector A Insert connector M40 female straight 9-pin
Plug Connector B Circuit board connection