Property | Details |
---|---|
Manufacturer Part No | IKL0021 |
Cable Type | Basic cable |
Number of Cores and Conductor Size | (4G1.5 + 2x(2×0.75)C)C |
Outer Diameter (max) | 14.5 mm |
Weight per km | 287 kg/km |
Copper Index | 167 kg/km |
Min. Bend Radius, e-chain (factor) | 7.5 × diameter = 108.75 mm |
Min. Bend Radius, flexible (factor) | 6 × diameter |
Min. Bend Radius, fixed (factor) | 4 × diameter |
Temperature Range e-chain® | -25°C up to +80°C |
Temperature Range, flexible | -40°C to +80°C (according to DIN EN 60811-504) |
Temperature Range, fixed | -50°C to +80°C (according to DIN EN 50305) |
Maximum Speed unsupported (v max.) | 10 m/s |
Maximum Speed gliding (v max.) | 5 m/s |
Maximum Acceleration (a max.) | 80 m/s² |
Nominal Voltage | 600/1,000 V (according to DIN VDE 0298-3) |
UL Voltage Rating | 1000 V |
Test Voltage | 4000 V (according to DIN EN 50395) |
Core Conductor | Stranded conductor, especially bend-resistant bare copper wires (DIN EN 60228) |
Core Insulation | Mechanically high-quality, low-capacity XLPE mixture |
Core Stranding | Power cores with control pair elements wound with elements for high tensile stresses |
Core Group 1 Core Structure | 4G1.5 |
Core Group 2 Core Structure | 2x(2×0.75)C)C |
Element Shield | Extremely bend-resistant braiding made of tinned copper wires |
Inner Jacket | TPE mixture adapted to e-chains® requirements |
Overall Shield | Extremely flexible braiding made of tinned copper wires; coverage approx. 70% linear, 90% optical |
Outer Jacket | Low-adhesion, halogen-free, highly abrasion-resistant PUR mixture (DIN EN 50363-10-2) |
Outer Jacket Color | Pastel orange (comparable to RAL 2003) |
CFRIP® | Tear strip molded into the inner jacket for faster stripping |
UV Resistance | Medium |
Oil Resistance | Oil-resistant (Class 3, according to DIN EN 50363-10-2) |
Offshore | MUD-resistant according to NEK 606 – status 2018 |
Flame Retardant | IEC 60332-1-2, Cable Flame, VW-1, FT1, FT2/Horizontal Flame |
Silicone-Free | Free from silicone affecting paint adhesion (PV 3.10.7 – status 1992) |
Halogen-Free | According to DIN EN 60754 |
UL Verified | Certificate no. V293650: “igus 4-year chainflex cable guarantee and service life calculator based on 2 billion test cycles per year” |
NFPA | According to NFPA 79-2018, chapter 12.9 |
DNV | Type approval certificate TAE00003XA |
REACH | According to Regulation (EC) No. 1907/2006 |
Lead-Free | According to 2011/65/EU (RoHS-II / RoHS-III) |
Cleanroom | ISO Class 1; outer jacket complies with CF77.UL.05.12.D, tested by IPA (DIN EN ISO 14644-1) |
DESINA | According to VDW, DESINA standardisation |
CE | According to 2014/35/EU |
Plug Connector A | Round plug, socket |
Plug Connector B | Open cable end |
©2025 EMI. All Rights Reserved.