Category | Specification |
---|---|
Manufacturer Part No | IKG4090 |
Cable Type | Basic cable |
Attribute | Value |
---|---|
No. of cores & cross-section | (4G4.0 + 2x(2×1.5)C)C |
Max. outer diameter [mm] | 17.5 |
Weight per km [kg] | 459 |
Copper index [kg/km] | 308 |
Attribute | Value |
---|---|
Min. bend radius, e-chain [x d / mm] | 7.5 / 131.25 |
Min. bend radius, flexible [x d] | 6 |
Min. bend radius, fixed [x d] | 4 |
Temp. (e-chain®) | -25°C to +80°C |
Temp. (flexible) | -40°C to +80°C (EN 60811-504) |
Temp. (fixed) | -50°C to +80°C (EN 50305) |
Max. speed (unsupported / gliding) [m/s] | 10 / 5 |
Max. acceleration [m/s²] | 80 |
Attribute | Value |
---|---|
Nominal voltage | 600/1,000V (VDE 0298-3) |
UL voltage rating [V] | 1000 |
Test voltage | 4000V (EN 50395) |
Attribute | Value |
---|---|
Conductor | Bare copper, stranded (EN 60228) |
Core insulation | Low-capacity XLPE |
Core stranding | Power + control pairs, high-tensile |
Core group 1 | 4G4.0 |
Core group 2 | 2x(2×1.5)C)C |
Element shield | Tinned copper braid |
Inner jacket | TPE for e-chains® |
Overall shield | 70% linear / 90% optical tinned braid |
Outer jacket | Halogen-free PUR (EN 50363-10-2) |
Outer jacket color | Pastel Orange (RAL 2003) |
CFRIP® | Tear strip inside jacket |
Attribute | Value |
---|---|
UV resistance | Medium |
Oil resistance | Class 3 (EN 50363-10-2) |
Offshore | MUD-resistant (NEK 606:2018) |
Flame retardant | IEC 60332-1-2, VW-1, FT1, FT2 |
Silicone-free | Yes (PV 3.10.7) |
Halogen-free | EN 60754 |
UL verified | V293650 (igus 4-year guarantee) |
NFPA | NFPA 79-2018, Ch. 12.9 |
DNV | TAE00003XA |
REACH | EC No. 1907/2006 |
Lead-free | 2011/65/EU (RoHS-II/III) |
Cleanroom | ISO Class 1 (DIN EN ISO 14644-1) |
DESINA | VDW Standard |
CE | 2014/35/EU |
Connector A | round plug, socket |
---|---|
Connector B | open cable end |
©2025 EMI. All Rights Reserved.
UNIT N, 17/F, CENTURY INDUSTRIAL CENTRE, 33-35 AU PUI WAN STREET, FOTAN, SHATIN, Hong Kong